Alarm and fire-fighting systems may be fully installed, with pipes, panels and detectors apparently in place, and then the first serious test reveals that the pump does not deliver the required pressure, the detectors are not connected to the panel, or sprinklers were moved to suit the decor so coverage is incomplete. An approved drawing alone does not guarantee correct installation. That is why there is a safety systems compliance report: the document proving that what was installed matches what was approved, and that it actually works. This guide explains what the report is, why it is required, what it contains, who prepares it, when it is required, and what follows operation.

What Is a Compliance Report?

An engineering report proving that safety and fire protection systems were installed according to the approved drawings and specifications, and have been tested and work as designed, before the building or facility is operated.

Why Is It Required?

  • An approved drawing alone does not guarantee correct installation.
  • The civil defense guide for warehouse buildings requires approved prevention and protection drawings consistent with the code and construction documents, meaning what is built must match what was approved.
  • It protects the owner before taking over the project from the contractor.
  • It supports licence applications and safety certificates. Read: The building compliance certificate.

What Does It Contain?

  • A comparison of what was built with the approved drawing for each system.
  • Operational test results: alarm, pumps, pressures, sprinklers and special systems.
  • Testing of interfaces between systems (the alarm with air conditioning, lifts and doors).
  • Observations, corrective actions and retesting.

Systems Covered by the Report

SystemWhat is verified
Alarm and detectionDetector locations, programming and panel response. Read: Alarm requirements
Pumps and networkPressure, flow, automatic and standby operation
SprinklersCoverage, spacing and valves
Standpipes and hose cabinetsPressure at the highest point and hose readiness
Special systemsRoom integrity and discharge sequence. Read: The FM-200 system
Lighting and signsEmergency lighting operation and battery duration

For the tests in detail: Why safety systems fail the final test.

When Is It Required?

  • Before operating a new building or taking it over from the contractor.
  • After significant modifications to the systems.
  • When the activity changes or the facility expands. Read: Changing a shop's activity.
  • When requested by the competent authorities or insurers.

After Operation

Compliance is a beginning, not an end; the Ministry of Municipalities' requirements for warehouses and workshops state that maintaining and preserving fire systems is the owner's responsibility, with periodic maintenance and calibration. Read: Keeping the safety certificate valid.

Frequently Asked Questions

Who prepares the compliance report?

An engineering office specialised in fire protection, preferably independent of the installing contractor.

Is it required for every building?

It depends on the project and authorities' requirements; it is essential practice in projects with integrated systems.

Is it different from the technical report on Salamah?

They are similar in inspection, but the compliance report focuses on matching what was built to what was approved and on operational testing. Read: The technical report and safety equipment certificate.

What if there are no approved drawings?

As-built drawings must first be prepared and assessed against the requirements. Read: Fire system drawings.

Does the report protect the owner from contractor defects?

Yes, because it documents observations before handover and requires them to be corrected.