Short answer: Safety and security systems fall into two groups: fire safety systems (alarms, automatic suppression, extinguishers, emergency lighting and signs, smoke control) required by Civil Defense and the Saudi Building Code; and security systems (CCTV, access control, intrusion alarms). What your building needs depends on its use, area, height and number of occupants, and is set during design before construction.

Key Points

  • The required system is set by the building's occupancy classification in the code, not the owner's preference.
  • System designs must be approved before installation, not after.
  • Systems are interlinked: the alarm shuts down air conditioning, opens smoke vents and recalls lifts.
  • Periodic maintenance and a maintenance contract are conditions for keeping the safety licence.

First: Fire Safety Systems

SystemFunctionUsually required in
Fire alarmDetecting smoke or heat and alerting occupantsMost non-residential and multi-storey buildings
Automatic sprinklersExtinguishing or controlling fire with water automaticallyLarge buildings, warehouses, malls and high-rise buildings
Hose reels and cabinetsManual firefighting from the fire water networkMulti-storey buildings and large facilities
Portable extinguishersPutting out fires at the startAll facilities
Special suppression systemsClean agent, CO2 or kitchen systemsServer and electrical rooms and restaurant kitchens
Emergency lighting and exit signsGuiding occupants during power failureAll public buildings
Smoke controlSmoke extraction and stair pressurisationHigh-rise buildings, malls and basements
Fire pumps and water tankProviding the pressure and volume neededBuildings with sprinklers or hose reels

Second: Security Systems

  • CCTV: required for a number of activities under the requirements of the competent authorities.
  • Access control: cards or biometrics for sensitive areas.
  • Intrusion alarms: for warehouses and shops outside working hours.
  • Intercom and public address: for guiding occupants during evacuation.

Important: security systems must not obstruct evacuation. Electronically controlled doors on escape routes must open automatically when the alarm sounds.

How Your Building's Requirements Are Determined

  1. Occupancy classification: residential, commercial, educational, healthcare, storage or industrial.
  2. Total area and area per floor.
  3. Building height, number of floors and basements.
  4. Number and nature of occupants (children, patients, guests).
  5. Stored materials and their hazard level.

How the Systems Work Together in a Fire

  1. A smoke detector signals the alarm panel.
  2. Sirens and warning lights activate throughout the building.
  3. Air conditioning stops to avoid spreading smoke, while smoke extraction and stair pressurisation start.
  4. Lifts return to the ground floor and stop normal operation.
  5. Electronic doors on escape routes open.
  6. Sprinklers in the fire zone activate as heat rises, starting the pumps.
  7. Exit signs and emergency lighting come on during power failure.

Any break in this chain reduces effectiveness, so integration is tested at commissioning and during periodic maintenance.

Design and Approval Stages

  1. Study code requirements for the occupancy.
  2. Design the systems and the hydraulic calculations for sprinklers and pumps.
  3. Prepare safety and evacuation drawings.
  4. Obtain approval from the competent authority as part of the building permit or Civil Defense licence.
  5. Install through an accredited safety contractor, then test and commission.
  6. Put a periodic maintenance contract in place.

What Affects the Cost of Safety Systems?

  • Building area and number of floors.
  • Whether sprinklers are needed, with the associated tank and pumps.
  • Special suppression systems for server rooms and kitchens.
  • Smoke control requirements in high-rise buildings and basements.
  • Equipment quality and approval.

Getting the design right from the start avoids the biggest cost: reinstalling after a failed inspection.

Periodic Maintenance

SystemMaintenance
ExtinguishersPeriodic inspection and refilling by type
AlarmTesting detectors, the control panel and batteries
Sprinklers and pumpsRunning pumps, testing pressure and control valves
Emergency lightingBattery operation tests

Common Mistakes with Safety Systems

  • Installing systems without an approved design, then failing inspection.
  • New false ceilings or partitions blocking detectors and sprinklers.
  • A tank or pump too small for the required calculations.
  • Unintegrated systems: the alarm does not stop air conditioning or release doors.
  • Neglecting maintenance until systems fail.

Safety and Security Systems with Abak Engineering Consultancy

We design and review fire protection systems to the Saudi code, prepare hydraulic calculations, safety and evacuation drawings and technical reports, and follow up approval with Civil Defense.

Request the service: Safety system design and review service | 0531145777

Frequently asked questions

What are safety and security systems?

Fire protection systems such as alarms, sprinklers, extinguishers and emergency lighting, and security systems such as CCTV and access control.

Who decides which safety systems my building needs?

The Saudi Building Code, based on occupancy classification, area and height, applied by the engineering office in the design.

Are sprinklers required in every building?

No. They depend on occupancy, area and height, and are common in warehouses, malls and high-rise buildings.

Do I need an approved design before installing safety systems?

Yes. Installing without an approved design may lead to rejection at inspection and rework.

Is CCTV a Civil Defense requirement?

CCTV is governed by other competent authorities for certain activities, while Civil Defense focuses on fire and evacuation systems.

Does Abak design fire systems?

Yes: design, hydraulic calculations, safety drawings and review.

Official Sources