MEP Engineering (Mechanical, Electrical & Plumbing)

Firefighting System Design

We design sprinkler and gaseous suppression systems, hose cabinets and pump rooms with full hydraulic calculations to NFPA and the Saudi Building Code.

  • Professional Engineering Team
  • Fast Service
  • High Quality
  • Trusted Engineering Solutions
Firefighting System Design
Overview

What is this service?

Design of the mechanical fire protection systems: automatic sprinkler systems, gaseous suppression systems (FM200 and CO2), fire hose cabinets, and the pump room with the appropriate pump selection. Hydraulic calculations are carried out both manually and in Elite, in accordance with NFPA, the local codes and Civil Defense requirements.

Why do you need this service?

Protects life and property and reduces fire risk.

A prerequisite for the Civil Defense permit and the safety certificate.

A design grounded in accurate, defensible hydraulic calculations.

Compliance with NFPA, the Saudi code and Civil Defense requirements.

How It Works

Service Preparation Steps

01

Facility study

We classify the hazard and study the building and its protection requirements.

02

System selection

The appropriate suppression systems (sprinkler / gaseous) are determined.

03

Calculations

Hydraulic calculations are performed manually and in Elite.

04

Pump room

The pump room is designed and the pumps selected.

05

Deliverables

Shop drawings and bills of quantities are produced.

06

Approval

The drawings are approved ready for submission to Civil Defense.

What does the service include?

Automatic sprinkler system design.
Gaseous suppression system design (FM200 / CO2).
Fire hose cabinets, pump room design and pump selection.
Hydraulic calculations (manual / Elite).
Shop drawings and bills of quantities.
Quality & Compliance

Approved Standards & Codes

NFPA fire protection codes
Saudi Fire Protection Code (SBC 801)
Civil Defense requirements
Salamah portal

Frequently Asked Questions About This Service

What is the difference between sprinklers and gaseous suppression?

Sprinklers suit most spaces, while gaseous suppression (FM200 or CO2) is used where water would cause damage — server rooms and electrical rooms. The choice follows the hazard classification and what the space contains.

Why are hydraulic calculations required?

Because they prove the required pressure and flow reach the most remote sprinkler on the network. Without them the design is an unproven claim — one of the most common reasons for rejection at Civil Defense review.

Does the design cover the pump room?

Yes — it covers the pump room design and pump selection to suit the network's size and pressure, along with hose cabinets and their distribution along the required access routes.

Why Choose abak?

We combine deep engineering expertise with high quality standards to deliver solutions you can trust.

Experienced Engineers

A team of certified consultants and engineers with long experience in the Saudi market.

High Quality Standards

Strict adherence to the Saudi Building Code and international engineering best practices.

Modern Engineering Solutions

We use the latest tools and technologies to deliver precise, efficient designs.

Professional Consultation

We listen to your needs and design the right solution for your project and budget.

Fast, Reliable Delivery

We commit to timelines and deliver our projects on schedule.

How It Works

How We Work With You

Clear steps from first contact to final delivery.

  1. 1

    Contact Us

    Reach us on WhatsApp or by phone and share your project details.

  2. 2

    Requirement Analysis

    We study your needs and set a clear, suitable engineering plan.

  3. 3

    Engineering Execution

    Our team executes the work precisely to the highest standards.

  4. 4

    Final Delivery

    We hand over complete deliverables with post-delivery support.

Ready to Start Your Project?

Reach our team now on WhatsApp and get a consultation tailored to your service.